Environmental laboratory

Environmental laboratory testing services

Field sampling and standard-method analysis of water, soil, waste, air, noise and workplace exposure for oil, gas, energy and industrial projects across Iraq.

Licensed environmental laboratory by the Iraqi Ministry of Environment (MOEN), Licence No. 987, and registered with the Iraqi Chemists Syndicate (ICS).

What we test

Five testing areas, one integrated laboratory. Every test follows the same controlled workflow: field sampling, preservation and transport, analysis, QA/QC review and reporting.

Reliable data behind every environmental decision

Atyaf Al-Kimiya | Spectra Chem™ operates a MOEN-licensed environmental laboratory in Iraq. Our field and laboratory teams work together from sampling plan to final report, delivering data for EIA/ESIA studies, baseline surveys, compliance monitoring and site investigations across Iraq.

Who we serve

  • Oil & gas operators
  • Refineries & petrochemicals
  • Power plants
  • Cement & steel
  • Infrastructure projects
  • Environmental consultants

Licences & accreditation

MOEN Licence No. 987

Environmental Laboratory

Issued 22 Apr 2026, valid to 22 Apr 2029

Verification code 646806818737575

Iraqi Chemists Syndicate

Certified chemical analysis laboratory (industrial & scientific), registered with the Iraqi Chemists Syndicate (ICS).

Quality assurance & control

  • Validated methods: SM, US EPA, ISO, ASTM, NIOSH
  • Calibrated instruments, traceable standards
  • Certified reference materials (CRMs)
  • Blanks, duplicates and matrix spikes per batch
  • Proficiency testing program (PTP) and external QA
  • Chain of custody and sample preservation

Analytical techniques

Chromatography

GC-MS, GC-FID, GC-ECD, GC-NPD, HRGC-HRMS, ion chromatography

Spectrometry

ICP-OES, ICP-MS, AAS (flame, graphite furnace and hydride), UV-Vis

Radiometry

Liquid scintillation counting (LSC), HPGe gamma spectrometry

Results are reported against Iraqi limits of the Ministry of Environment (MOEN), Ministry of Health (MOH), Ministry of Water Resources (MOWR), Ministry of Oil (MOO) and the Central Organization for Standardization and Quality Control (COSQC), and against international guidelines (WHO, IFC EHS, US EPA) or project-specific lender standards.

Test packages by application

The key tests for each purpose. These are typical parameter sets we recommend; every package is adjusted to the applicable permit, regulation or client specification.

Drinking & bottled water

Colour, turbidity, pH, TDS, hardness, major ions, nitrate, nitrite, fluoride, As, Pb, Cd, Hg, Cr, THMs, coliforms, E. coli

IQS 417, WHO guidelines

Produced water & brine

TDS, salinity, density, chloride, Ba, Sr, Fe, oil-in-water, BTEX, PAHs, NORM, corrosion bacteria (SRB, APB)

Re-injection and disposal permits

Industrial effluent & self-monitoring

pH, BOD₅, COD, TSS, oil & grease, phenols, sulfide, cyanide, ammonia, heavy metals, toxicity

Law No. 25, IFC EHS

Sanitary wastewater & WWTP

BOD₅, COD, TSS, nitrogen, phosphorus, MLSS, MLVSS, SVI, coliforms, helminth eggs, jar test

Treatment performance and reuse

RO, boiler & cooling water

SDI, LSI, Ryznar and Puckorius indices, silica, hardness, alkalinity, iron, conductivity, hydrazine, MIC bacteria

Scaling and corrosion control

Swimming pools & bathing water

Free and combined chlorine, cyanuric acid, pH, turbidity, E. coli, Pseudomonas aeruginosa, Legionella, Staphylococcus aureus

Public health compliance

Irrigation & agriculture

EC, TDS, SAR, sodium %, boron, chloride, bicarbonate, nitrate, pH; soil available nutrients

FAO Irrigation & Drainage Paper 29

Aquaculture & livestock water

Dissolved oxygen, ammonia, nitrite, H₂S, alkalinity, hardness, pH, metals, coliforms

Stock health and productivity

Contaminated land & drilling waste

TPH bands, BTEX, PAHs, metals, Cr(VI), PCBs, chloride and salinity, TCLP leachate

Site investigation and closure

Hazardous waste & export

TCLP (42 analytes), PCBs, total halogens, metals, hazardous characteristics for classification

US EPA 1311, BS EN 12457, Basel Convention

Stack & ambient compliance

Stack O₂, CO, NOx, SO₂, dust, HCl, HF, PCDD/F; ambient PM10, PM2.5, NO₂, SO₂, O₃, H₂S

Iraqi emission limits, IFC EHS

Water and effluent testing follows Iraqi Water Law No. 25 – System of Rivers and Other Water Resources Protection (discharges to rivers and receiving-water quality). Drinking water is assessed against Iraqi Standard No. 417 – Standard Specification for Drinking Water (physical, chemical and microbiological limits).

Not sure which package applies? Send us the permit, regulation or project scope and we will propose the parameter list.

Water, wastewater & brine analysis

Matrices: drinking water, groundwater, rivers & lakes, seawater, pool water, RO & process water, produced water & brine, wastewater & effluents

Physical & general

Temperature, colour, pH, EC, resistivity, turbidity, TDS, TSS, TS, fixed and volatile solids, settleable solids, density, viscosity, salinity, ORP, DO

SM 2000 series, ISO 10523, ISO 7027

Organic load & sum parameters

BOD₅, COD, TOC, DOC, AOX, TOX, permanganate index, fat, oil & grease, phenols, MBAS and non-ionic surfactants

SM 5210, SM 5220, SM 5310, ISO 9562

Anions & nutrients

Cl, SO₄, F, Br, I, NO₃, NO₂, PO₄, chlorite, bromate, HCO₃/CO₃, ammonium-N, TKN, total N, total P

Ion chromatography, SM 4110 B, ISO 10304-1

Inorganic non-metals

Free and WAD cyanide, sulfide, sulfite, free sulfur, free chlorine, chloramines, hydrazine, silica, free CO₂, cyanuric acid

SM 4500 series, ASTM D1385

Metals & elements

75 elements incl. heavy metals, rare earths and precious metals; Cr(VI), Fe²⁺/Fe³⁺, Hg

ICP-OES, ICP-MS, AAS, EPA 200.7, SM 3120/3125

Volatile organics

Priority VOCs, BTEX, MTBE, trihalomethanes, 9 haloacetic acids, volatile fatty acids

GC-MS, GC-FID, headspace

Semi-volatile organics

21 PAHs, alkylated NPD, SVOCs, dioxins & furans, 7 phthalates, 30 phenols, chlorinated hydrocarbons, nonylphenols and bisphenol A

EPA 8270 E, EPA 3510 C

Pesticides, herbicides & PCBs

52 organophosphorus and 36 organochlorine pesticides, phenoxy herbicides, PCB congeners and Aroclors

EPA 8141 B, GC-ECD / GC-NPD

Petroleum hydrocarbons

Aliphatic and aromatic TPH bands (C6–C35), nC10–nC40, hydrocarbon oil index, mineral oils

EPA 8015 B, GC-FID

Microbiology & biology

22 tests incl. coliforms, E. coli, enterococci, Legionella, Pseudomonas, Salmonella, Vibrio, helminths; plankton and benthic species

SM 9000 series, ISO 9308-1, ISO 11731

Jar test, scaling & process control

Jar test for water and wastewater treatability (coagulant and flocculant dosing); LSI, Ryznar and Puckorius indices, SDI (5/10/15 min), MLSS/MLVSS, SVI

ASTM D4189, ASTM D2035

Water sampling

Lakes, rivers, sea, wastewater and groundwater sampling; microbiological sampling

ISO 5667 series, ISO 19458

Compared with Iraqi drinking-water, effluent-discharge and river-protection limits, WHO guidelines and IFC EHS effluent guidelines.

Soil, sediment, sludge & waste

Contamination screening, site investigation and waste classification for oilfield, industrial and brownfield sites.

Matrices: soil & contaminated land, bottom sediment, sewage & treatment sludge, drilling cuttings & mud, oily sludge & tank bottoms, waste & flare pits, waste oil, biota

Sample preparation & digestion

Drying, crushing, splitting, pulverising; aqua regia, microwave, HF multi-acid, lithium borate and peroxide fusion, saturated paste

Physical & general

Moisture, dry matter, bulk and particle density, texture, structure, pH, EC, total salts, loss on ignition (550 °C), ash

Organic carbon & sum aggregate parameters

TOC, DOC, organic matter, TOX, oil and grease, hydrocarbons, phenol index, linear alkyl sulfonates

Inorganic parameters

Cr(III) and Cr(VI), cyanide, thiocyanate, anions, total nitrogen, phosphorus, silica

Metals & elements

75 elements by ICP-OES / ICP-MS and AAS after acid or microwave digestion

Organic contaminants

TPH bands, BTEX, VOCs, SVOCs, PAHs, NPD, PCBs, dioxins & furans, OC/OP pesticides, herbicides, phenols, chlorinated hydrocarbons

TCLP leaching

42 regulated analytes: 8 metals, VOCs, SVOCs, pesticides, herbicides and TPH-TCLP

US EPA 1311

Waste oil & biota

PCBs, polychlorinated terphenyls, phthalate esters, total halogen and chloride in waste oil; organics and metals in biota

Agricultural soil & fertility

Available phosphorus and potassium, DTPA-extractable Fe, Mn, Zn and Cu, calcium carbonate equivalent, organic carbon, soluble cations and anions, SAR

Typical applications

  • Drilling wasteCuttings and mud classification before disposal or treatment
  • Pits & spillsWaste-pit closure and spill impact assessment
  • RemediationBaseline, progress and close-out verification

Radioactivity / NORM and dioxin testing of soil, sludge, ash and waste: see Specialist analyses.

Ambient air & stack emissions

Ambient air: gases

NO₂, SO₂, O₃, CO, H₂S, NH₃, HF, HCl, mercaptans

Ambient air: particulates

PM10, PM2.5, TSP and deposited dust; 19 metals in PM10 and deposited dust

Ambient air: organics

150+ VOC vapours, BTEX, PCDD/PCDF

EPA TO-9A (dioxins)

Stack: combustion gases

O₂, CO, CO₂, NO/NO₂/NOx, SO₂, SO₃, H₂S, total gaseous organic carbon, moisture, velocity and flow

EN 15058, EN 14792, EN 14791, EN 12619, EN 14789

Stack: acid gases & dust

HCl, HF, HBr, Cl₂, HCN, NH₃, H₂SO₄ mist, total fluoride; particulate matter 5–1000 mg/m³, smoke density

EN 1911, EN 13284-1, ISO 9096, EPA 5 / 26A

Stack: trace organics & odour

Gas- and particle-phase PAHs, PCBs, PCDD/F and dl-PCBs, formaldehyde, odour concentration

EN 1948-1 to 4, ISO 11338, EN 13725

CEMS quality assurance

QAL2 and annual surveillance tests for CO, NOx, SOx, O₂, HCl, HF, TOC, dust and flow

EN 14181

Mobile sources

CO, CO₂ and hydrocarbon sampling from vehicles and mobile equipment

How we measure

  • Direct-reading analysersNDIR, paramagnetic, chemiluminescence
  • Isokinetic samplingParticulates, metals, PCDD/F
  • Sorbent & passiveTubes and diffusion samplers
  • Dispersion modellingConcentration contours at receptors

Noise

Measurement

Environmental sound pressure levels (LAeq, LAmax, LAmin, L10, L90), sound power of machinery and multisource industrial plant

ISO 1996-1/2, ISO 3744 / 3746, ISO 8297

Modelling & mapping

Outdoor propagation modelling, noise contour maps and receptor assessment

ISO 9613-2

Occupational hygiene & workplace exposure

Personal and area sampling to assess worker exposure against occupational exposure limits, using recognised NIOSH, OSHA and ISO methods.

Workplace dusts

Total and respirable dust, crystalline silica, carbon black, alkaline dusts, rubber process dust and fume

NIOSH 0600 series, NIOSH 7601

Asbestos

Asbestos identification in bulk and solid materials by polarised light microscopy

NIOSH 9002

Metals in workplace air

40 elements incl. Pb, Cd, Cr, Mn, Ni, As, Be, Co and Zn; hexavalent chromium

Filter sampling, ICP-AES, NIOSH 7300 / 7600

Acids & inorganic gases

HF, HCl, HBr, HNO₃, H₂SO₄, H₃PO₄, particulate fluoride, HCN, CO, NOx, O₂

Ion chromatography, NIOSH 7903 / 6604, OSHA ID-196

Organic vapours

VOCs, formaldehyde and PAHs by sorbent-tube sampling

GC-FID, GC-MS, NIOSH 3500

Bioaerosols & indoor air

Airborne bacteria and fungi in offices, camps, control rooms and clinics

NIOSH 0800

Thermal comfort

PMV and PPD indices for moderate thermal environments

ISO 7730

Workstation noise

Emission sound pressure levels at work stations and specified positions

ISO 11201, ISO 11204

Specialist testing for complex matrices

Dedicated workflows for persistent organic pollutants, naturally occurring radioactivity, oilfield corrosion, asbestos and PFAS, together with benthic ecological studies.

Dioxins & furans (PCDD/PCDF)

Compounds
17 toxic 2,3,7,8-substituted PCDD/PCDF congeners, dioxin-like PCBs and PCB congeners
Workflow
Isokinetic, ambient or matrix sampling, then isotope-dilution extraction and clean-up, HRGC-HRMS analysis and a WHO-TEQ / I-TEQ report
Matrices
Stack gas, ambient air, water, soil, sediment, sludge, waste oil and biota
Methods
EPA 1613 B (water, solids), EN 1948-1 to 4 (stack), EPA TO-9A (ambient air)

Benthic studies

Scope
Benthic macroinvertebrates and bottom-dwelling organisms in rivers, lakes, marshes and coastal sediments
Parameters
Taxonomic composition, abundance and density, biomass, diversity indices (Shannon–Wiener, Simpson), biotic indices and EPT taxa
Methods
Grab, corer and kick-net sampling; sieving, sorting and microscopic identification (ISO 10870, ISO 16665)
Use
EIA/ESIA baselines and monitoring of discharges, dredging and river crossings

Radioactivity & NORM

Parameters
Gross alpha, gross beta; K-40, Ra-226, Th-232, I-131, Rn-222; total uranium
Methods
Liquid scintillation counting (ISO 11704); HPGe gamma spectrometry (ISO 10703)
Matrices
Drinking and produced water, brine, soil, sludge, scale, sediment, waste
Use
Waste classification and worker exposure screening

Microbiologically influenced corrosion (MIC) bacteria

Bacteria
SRB, APB, IRB, IOB, GHB, NRB
Method
Serial-dilution culture, NACE TM0194
Matrices
Produced, injection and process water; seawater and brine
Use
Corrosion risk and biocide performance monitoring

Asbestos

Scope
Identification of asbestos types in bulk building materials, insulation, soil and waste
Method
Polarised light microscopy (NIOSH 9002)
Use
Demolition surveys, waste classification and worker protection

PFAS

Parameters
PFOS, PFOA, PFHxS and extended PFAS lists
Methods
LC-MS/MS per US EPA 537.1, 533 and 1633
Matrices
Drinking, ground and waste water; soil and sediment; firefighting foam

From sample request to regulator-ready report

  1. FieldRequest & scopeParameters, limits and site details
  2. FieldSampling planLocations, frequency and containers
  3. FieldField samplingTrained teams and field measurements
  4. FieldPreserve & shipCold chain and chain of custody
  5. LaboratoryLab receiptSample check, coding and registration
  6. LaboratoryAnalysisValidated methods, calibrated instruments
  7. Quality gateQA/QC reviewBlanks, duplicates, spikes and CRMs. If QC criteria are not met, the samples are re-analysed before anything is reported.
  8. ReportingReportResults vs Iraqi and international limits
  • CoverageField sampling and shipping throughout Iraq
  • TurnaroundStandard: X working days. Urgent service available.
  • IntegratedLab data feeds directly into our EIA, ESIA and monitoring studies

Send us your parameter list or project scope

We will propose the test schedule, sampling plan and applicable limits for your site.

What to send us

  • Parameters or standardYour parameter list or the regulation / permit limits to comply with
  • Sample matrix & quantityWater, soil, waste, air, noise or workplace, and number of samples
  • Site & scheduleLocation, access requirements and sampling dates
  • Turnaround & formatRequired delivery time and reporting format
Offices
Baghdad / Erbil, Iraq